Schemas / Modular

rig.modular.power

v1.4.0 · stable maturity: draft 4 fields 1 required

Fields

FieldTypeMeaning
header enumidc-10 · idc-16 required idc-10, idc-16
positive12MilliAmps float0 – * optional Optional. Draw from +12 V (mA). Absent = not stated. Absent is not 0
negative12MilliAmps float0 – * optional Optional. Draw from -12 V (mA). Absent = not stated. Absent is not 0
positive5MilliAmps float0 – * optional Optional. Draw from +5 V (mA). Absent = not stated. Absent is not 0

What a module draws, and which header it draws it through. Format when present.

Compose on the rig.modular.module entity. The header's contacts are not fields here: they are rig.circuit.pin children of a rig.circuit.part, each pointing at a rig.circuit.net. Pin 1's function is how a host knows the cable is not reversed.

Required: header.

A stated 0 means the module draws none of that rail. An omitted current means the author did not say. A supply sized from an omission will be short. EuroSynth's 10-pin header and the 16-pin header it still has to meet: eurosynth.md.

JSON Schema

Resolves at https://rig.works/schemas/rig.modular.power.schema.json — raw file.

{
  "$schema": "https://json-schema.org/draft/2020-12/schema",
  "$id": "https://rig.works/schemas/rig.modular.power.schema.json",
  "title": "rig.modular.power",
  "type": "object",
  "additionalProperties": false,
  "properties": {
    "header": {
      "type": "string",
      "enum": [
        "idc-10",
        "idc-16"
      ]
    },
    "positive12MilliAmps": {
      "$ref": "./_defs.schema.json#/$defs/float",
      "minimum": 0
    },
    "negative12MilliAmps": {
      "$ref": "./_defs.schema.json#/$defs/float",
      "minimum": 0
    },
    "positive5MilliAmps": {
      "$ref": "./_defs.schema.json#/$defs/float",
      "minimum": 0
    }
  },
  "required": [
    "header"
  ],
  "x-rig-maturity": "draft"
}

Seen in